what gauge copper wire for grounding

aldi logistics scheduling » 2025 aau basketball team rankings » what gauge copper wire for grounding

Arrives by Wed, Mar 15 Buy 22 Gauge 15m Red Black Zip Wire AWG Cable Ground Stranded Copper Car at Walmart.com If you dont know whether your generator needs grounding or how to do it, you should follow the rest of this guide to make sure youre staying safe. A grounding wire on the other hand is a safety wire that has intentionally been connected to earth. Southwire 47175505 Romex SIMpull NMD90 Copper Wire Electrical Cable with Ground, 12-3, Yellow, 16.4-ft W W W Southwire 47175505 Romex SIMpull NMD90 Copper Wire Electrical Cable with Ground, 1 . Because the rod or the rebar is technically a grounding electrode, this ground wire is correctly called a grounding electrode conductor. A conducting object through which a direct connection to earth is established. Part of the problem is that the word ground has been used imprecisely for more than a century to describe electrical activity or components. Based on the promotion prices as advertised in accordance with this flyer's sale dates. If the generator only feeds power to electrical equipment mounted on it or connected to it by extension cords and plugs through power receptacles mounted on it. Power is received from the utility service lines and flows through the outside electrical meter base and into the main electrical panel in an attached garage, basement, or interior room. You can use either a 2-inch or 2.5-inch conduit based on the fill space you intend to occupy inside the conduit. In Dungeon World, is the Bard's Arcane Art subject to the same failure outcomes as other spells? 25 ft. 6-Gauge Solid SD Bare Copper Grounding Wire Compare Top Rated ( 218) Model# 10644390 Southwire (By-the-Foot) 4-Gauge Solid SD Bare Copper Grounding Wire Compare Model# 57996202 Southwire 2,500 ft. 10 Black Stranded CU Photovoltaic XLP 2KV Cable Compare Top Rated More Options Available ( 220) Model# 10638590 Southwire Keep in mind that the area of the wires must be less than 40% of the internal space of the pipe when 3 or more wires are present. Additional information for residents of Quebec only:The regular annual rate for persons applying for the Triangle Mastercard and the Triangle World Elite Mastercard is 22.99% for cash transactions and related fees and 19.99% for all other charges. The grounding wires are safe to touch unless there is an electrical surge that causes electricity to flow through the grounding wire. You can loosen it with pliers or a wrench. It can also be used to make jewelry. If you consult the copper ground wire size chart above, you can see that you will need a 2 AWG copper ground wire to adequately ground a 250 kcmil wire. And if the information here was valuable to you, share it with your friends and family. (NEC), kcmil Wire Size Chart (Ampacity Of 250-2000 MCM Wires), AWG To mm2 Chart + Calculator (0-40 AWG To mm2), What Temperature To Leave A Vacant House In Summer? The thicker the electrical wire, the lower the gauge - and the more current it can carry without resistance. Example: 1 AWG copper wire doesnt require a 1 AWG copper ground wire. 2023 The Taunton Press, Inc. All rights reserved. The modal window is a 'site map' of the most critical areas of the site. Let's look at the NEC recommendations for aluminum wires as well: For some high-current applications, conductor sizes beyond the practical size limit of round wire are required. The NEC article 250.53(B) requires you to space grounding rods at least 6 feet apart, connecting by a grounding wire. You will use your sledgehammer and block to drive your copper ground rod at least eight feet into the ground. We reserve the right to limit quantities. Thanks for contributing an answer to Home Improvement Stack Exchange! copper-clad steel rods at least 8 ft. long. Its nearly impossible to accurately price the cost of installing a 200 amp entry service in a house. Excel App. /TMUnless otherwise noted, all trademarks are owned by Canadian Tire Corporation, Limited and are used under licence. How Childbirth Affects Your Relationship? As you may know, the ground wire doesnt have to be as big as the main wire. Consider doing an electrical load calculation before committing to a 200 amp electrical panel. Physics So by now, you have concluded that you need to ground your portable generator with a separate grounding rod to an external ground. smaller bare conductor diameters than those shown. This is also why people confuse it with being a 100 amp wire. Electronics Instrumentation Call a local licensed electrician or your city for specific guidelines. The larger the gauge number, the smaller the wire actually is. Its not the most fun project in the world, but if you stick with our five steps for grounding, your generator will be safe to use. AWG wire for 200-amp service requires either #2/0 copper wiring or #4/0 aluminum or copper-clad wiring. Cloudflare Ray ID: 7a2df9bb986b7c9e Its a fastener that allows you to connect copper wire tightly to the grounding rod. Save my name, email, and website in this browser for the next time I comment. This is from a different table of sizes (for grounding electrode conductors) as opposed to ground wires from main panel to subpanel . Hole Diameter; 3/16 " 1/4 " 3/8 " Component. These are the most common colors used in electrical wiring. Also, the wire should not . This website is using a security service to protect itself from online attacks. Applicable on select styles/size. The frame of any portable generator is fabricated from metal and may become live in case of a ground fault. You can email the site owner to let them know you were blocked. Instead, youll want to plug into a power source. The wire size for 200 amp service is #2/0 AWG copper or #4/0 AWG for aluminum wire inside a minimum of 1.5-inch schedule 40 or 80 PVC conduit for underground electrical service. You can check what size wire you need for 100 amps here. The grounding electrodes primary functions are to divert lightning and other outside high voltages to the earth before they can damage the buildings electrical system, and to provide a ground reference. Visit triangle.com for full program rules and Partner location information. According to Article 250, for such portable generators. Solid and stranded bare copper (Classes AA & A) are used for overhead transmission and distribution applications. This type of copper wire is not covered in any type of protective coating, making it completely unprotected, hence the name. Can a ground wire be too big? Although the grounding electrode system (GES) is connected to the equipment grounding system at the service panel, the GES has virtually nothing to do with reducing hazards from problems in the wiring inside the house. Is there a proper earth ground point in this switch box? You dont bond the neutral and ground bars inside subpanels. Balances under $10 are due in full. How to Ground Solar Panels Drive an 8 foot long copper plated rod into the ground at least 8 feet deep. Once the ground rod is far enough into the soil, you can stop hammering. The return path in a typical house electrical circuit is through the white neutral wires that bring current back to the main panel. Before equipment-grounding conductors (popularly called ground wires) were widespread, people could be electrocuted when they came in contact with voltage that, due to a fault like a loose wire, unintentionally energized the metal casing of a tool or an electrical appliance. Conditions apply. Tankless Water Heater Wire Size Calculator: What Gauge Wire (AWG)? Wire Gauge Equivalent. Have you enjoyed our list of steps for grounding a generator? Why? Calculator + Chart (Natural Gas), Average Gas Bill For 1-Bedroom Apartment: State-By-State Cost Analysis, Average Electricity Bill For 4 Person Household (Survey Analysis), How Many kWh Per Day Is Normal? Southwire Underground Electrical Cable Copper Electrical Wire Gauge 12/3. It only takes a minute to sign up. Exposed Grounding Wires Grounding wires do not have electric current running through them most of the time, and commonly have exposed wires and connections. Online transactions must be fulfilled by the store during the offer period to qualify. This solid Copper Grounding Electrical Wire is used for electrical system and equipment grounding. Rewards are in the form of electronic Canadian Tire Money (CT Money). We are a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for us to earn fees by linking to Amazon.com and affiliated sites. Quantities may be limited. Pumps Applications Jun 13, 2011 (Edited) For 200 amp service use a 4 gauge copper wire from the panel to the water pipe (within 5 feet of where it enters the house and also between where it enters and the meter). DoItYourself.com, founded in 1995, is the leading independent I've been conducting professional home inspections since 2002. Engineering Materials, AWG Copper Wire Table Size and Data Chart @ 100 Degrees F. The American Wire Gauge (AWG) measurement system was designed with a purpose: for every three steps in the gauge scale, wire area (and weight per unit length) approximately doubles. The size of the primary bare copper conductor may need to increase for various reasons, including the length of the run, available fault current, or any number of reasons. So, a 2 conduit will suffice, or you can upsize to 2.5 if you wish for ease of pulling. What Gauge Copper Wire For Grounding This solid Copper Grounding Electrical Wire is used for electrical system and equipment grounding. The ground wire never carries normal circuit current. Hardware, Imperial, Inch Why is ground wire smaller gauge? and a picture to help make things a bit more clear. Second, should the GFCI fail, it must be self-locking: Current will cease to flow, so that the device must be replaced. The main electrical service may need to be disconnected entirely in existing homes to install the 200 amp service. Although a square or rectangular cross-section is very common for busbar shape, other shapes are used as well. On the other end of the wire, make sure that the end is completely attached to the ground bar in order to eradicate the possible loosening of the ground wire completely. The Importance of True Gauge Power & Ground Cable. The Triangle Mastercard and the Triangle World Elite Mastercard do not have an annual fee. | Contact, Home Carefully fix the ground wire until it reaches the ground rod located outside the house. Conditions and restrictions apply. The neutral circuit is bonded to the frame in most modern generators, particularly stand-by and open-frame ones. submitted to our "DoItYourself.com Community Forums". (1000-3000+ Sq Ft Homes), Thermostat Says Heat On But No Heat? The longer a wire runs, the more voltage loss occurs. The bigger ground wire doesnt do any harm to the system. The ground wire is intended to be a low-impedance path to ground, to safely carry the current of a ground fault until the circuit breaker trips. Applications and Design Manufacturing Processes All the metal parts that are not designed to carry any current, such as internal combustion engines, the fuel tank, and the generator housing, are bonded to the metal frame. If you encounter hard ground, you can wet it down a bit to loosen the soil, and you can drive the rod at a bit of an angle to make it easier in rocky terrain. One such major condition is when the portable generator feeds power to the home, office, trailer, shop, etc., through a transfer switch. A wire runs from this bar to a long copper rod which is physically pounded into the dirt (aka 'ground'). Using conductors having coated strands, different stranding type, and, especially, other temperatures changes the resistance. Grounding means electrically wiring parts of the solar system to the earth (earthling). The voltage drop and length of the wiring determine which wire is used. Long runs require a thicker gauge wire. With these two charts, you can pretty much figure out how big equipment grounding conductors you need. In fact, in those applications each of the strands may be 10, 12, 14, or 16 gauge. This 250.66 NEC table is also known as the equipment grounding conductor size chart. No international standards, follow the electric code for your region/. 6-gauge are used for cook tops and ranges carrying 40-50 amps. The conductors, usually bare copper or green insulated wire, create an effective path back to the main service panel in case the equipment becomes energized. If you apply the NEC 80% rule, 250 kcmil wire can handle up to 204 amps. According to Chapter 9, Table 4 of the 2017 NEC, a 2, Schedule 80 PVC conduit has 742mm2 usable fill. Finishing and Plating Buy #4 AWG Solid Bare Copper Wire (100ft cut) at Amazon. NEW NO BOX * Details about SMC AR20-N01-Z. It can be a size bigger or smaller than other wires. Bare copper ground wires do not need to be capped. Just make sure you follow the electrical code. These short wires should be called bonding conductors or bonding jumpers., The bare copper or green insulated wires in all modern circuits, which ultimately connect electrical equipment, such as receptacles and fixtures, to the service panel neutral/ground bar. What Size Wire Is Needed For 200Amp Electrical Service Home Inspection Insider, What size wire do I buy for my electrical service panel? You should always follow the instructions in the owners manual for your RV to ensure you ground the vehicle properly when youre plugged into a power source. COLIBYOU GROUND WIRE 4 AWG GAUGE SOLID BARE COPPER 200A - 50 FT. Wirenco 4 AWG Solid Bare Copper Building Wire (200 FT Cut) 75 Feet (23 Meter) - Insulated Solid Copper THHN/THWN Wire - 10 AWG . Coil Annealed - Dead Soft This site is protected by reCAPTCHA and the Google. Now you can attach a piece of hardware called a grounding lug. There are various international standards that are trending towards "homologation" or which are being reissued under other standard numbers with no technical changes. Click to reveal Bulk items will only be delivered within a 100km radius of the Store. You should know the rules to ensure your work is in compliance. These resistance values are valid only for the parameters as given. Friction Engineering You are always better off following the manufacturers instructions if you do or do not require grounding before use. The minimum size ground wire for 200 amp is #4 AWG bare copper conductor or #2 AWG aluminum, according to Article 250 of the 2020 NEC. 2023 Copyright Canadian Tire Corporation. Become a member and get unlimited site access, including the The following table reflects wiring size, length, and voltage drop:https://youtu.be/KKZ_Py-wyGgVideo cant be loaded because JavaScript is disabled: What size wire do I buy for my electrical service panel? Copper has high conductivity, wont rust, and is oxidation-resistant. 1. Southwire 12/2 NMD90 75M Romex SIMpull Electrical Wire - Red (22) $262 And. Below are some things to consider when trying to figure out what gauge copper wire for grounding. You can use a sturdy stepladder or dig a small hole and set the rod in it to make it shorter before you hammer. The NEC is a safety guide. Strength of Materials The ground only needs to carry current long enough to trip the breaker. For very large wire sizes (fatter than 4/0), the wire gauge system is typically abandoned for cross-sectional area measurement in thousands of circular mils (MCM), borrowing the old Roman numeral "M" to denote a multiple of "thousand" in front of "CM" for "circular mils." Wiring Project Guide. Electric Motor Alternators Get complete site access to expert advice, how-to videos, Code Check, and more, plus the print magazine. No votes so far! By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. Long runs require a higher gauge wire to minimize voltage drop. The 200 amp wire size must handle the system's high current demands and ensure . With too-small a ground wire, the breaker cannot magnetic-trip because it cannot flow enough current to hit 10x, because of the too-high resistance of the wire. This articles 200 amp size wire is from the NEC code and may vary from your local building code. for 200 Amp services, a #4 grounding electrode conductor (ground wire) is required. CANADIAN TIREand the CANADIAN TIRE Triangle Design are registered trade-marks of Canadian Tire Corporation, Limited. Grounding and bonding are a means to prevent the risk of shocks and electrocutions. GearIT 8 Gauge Wire (25ft Each- Black/Red Translucent) Copper Clad Aluminum CCA - Primary Automotive Wire Power/Ground, Battery Cable, Car Audio Speaker, RV Trailer, Amp, Electrical 8ga AWG 25 Feet 510 $1499 - $3899 FREE delivery Small Business 6PCS Split Bolt Connector Copper Grounding Clamps for Completing Ground Bonding to Bare Wires TJ-10 5 Grounding the frame diverts the fault current to the ground and brings the generators frame to the ground potential, eliminating any risk of an electrical shock. In Chapter 9, Table 5A of the 2017 NEC, a #4/0 Aluminum stranded conductor takes up 176.3mm2 of fill space. No idea about international standards, though. American Wire Gauge (AWG) is the US standard for sizing electrical wiring. Copper Electrical Wire & Cable at Lowes.com Popular Wire Types Non-Metallic Wire 10 Gauge 12 Gauge 14 Gauge TFFN & THHN Wire 6 Gauge 10 Gauge 12 Gauge UF Wire 10 Gauge 12 Gauge 14 Gauge Service Entrance Cable 2 Gauge 4 Gauge 6 Gauge Armored Cable 10 Gauge 12 Gauge 14 Gauge Power Cord 10 Gauge 12 Gauge 14 Gauge Electrical /Electrical Wire & Cable Generators are no exception to the grounding rule. /TMMastercard and World Mastercard are registered trademarks, and the circles design is a trademark of Mastercard International Incorporated. Pressing the Escape (ESC) button will close the modal and bring you back to where you were on the page. Your IP: The green represents the fact that it is an outdoor grounding wire. Third, GFCIs installed less than 5-1/2 ft. above floor level must be tamper-proof, with plastic shutters that slide across terminal slots to prevent, say, a child from inserting something into a slot. = 4.5 x CFM x h (std. 1-ft 18-Gauge Stranded Soft Drawn Copper Bare Wire (By-the-Foot) Model # 55024745. Keeping this in consideration,what gauge should a grounding wire be? The smaller the gauge Number the larger the conductor size. By "installation" I mean any metallic stuff such as the steel structure of the building, the case of an electrical panel, and so on. This type of copper is generally used in residential homes and probably has the best conductive properties, without being protected by insulation. Friction Formulas Apps Runs over 100 ft transition from AWG to kcmil wire, a thicker wire for greater distances. Dealers may sell for less. Any bonus multiplier is based on the base rate of collecting CT Money. air), Sensible Heat (BTU/hr) = 1.1 x CFM x t (std. The aluminum wire is slightly cheaper, but the copper wire will be more durable and have less voltage drop. Its important to start with a long copper grounding rod because it needs to be driven to a depth of at least four feet. That means it needs to travel further to reach the right depth if its at an angle. Consider the electrical circuit of your home fed from a utility source. For example, a typical 60A residential panel in the US requires a 10-gauge wire, and a 100A panel requires an 8-gauge per the US National Electrical Code. Free shipping for many products! Your local code will adopt or alter the NEC codes to fit their requirements. The type of electrical wire you need will vary depending on your electrical system. However, the aluminum gauge will be higher due to its reduced conductivity and heat resistance properties. Many electrical contractors use #4/0 aluminum or copper-clad 200 amp wire size. 210.65.88.143 Most 120Vac household circuits are fine using a 12 or 14 gauge wire. Visithttps://triangle.canadiantire.ca/en.htmlfor more information. Customer reviews and photos may be available to help you make the right purchase decision! There are several actions that could trigger this block including submitting a certain word or phrase, a SQL command or malformed data. It is also used as a residential grounding wire. Keeping this in consideration,what gauge should a grounding wire be? This is all from NEC, Article 810 that deals specifically with antenna grounding. For feeder runs of 50 ft and 75 ft, use a 200 amp wire size of #4/0 AWG aluminum wire. In stock and ready to ship. In case the equipment becomes energized by a hot wire touching a metal cover or other part, this conductor allows high current to flow safely and trip the breaker. The more power your generator can produce, the heavier the gauge of ground wire required to ground it. Therefore, the HomeAdvisor cost averages seem to be reasonably accurate. Using indicator constraint with two variables. Measures 1 ft. L. Solid and stranded (classes AA and A) bare copper are suitable for overhead transmission and distribution applications. Further, we will focus more on the grounding requirements of a portable generator in our article. Power Transmission Tech. What size conductor do I need to bond water and gas piping? Reference: Handbook of Scientific and Engineering Data In this case, you would become part of the circuit, with current flowing through you. You can use aluminum and copper for a 200 amp panel wire size. Thermodynamics Fluids Flow Engineering Grounding Electrode Conductor. The transfer switches must transfer the neutral to the generator. Economics Engineering Most inverter portable generators have their neutral floating. Pressure Vessel However, we recommend 2 or 2.5 inches if running three wires in the same conduit. The CO is issued after the electrical work has passed the building inspection. To ensure our content is always up-to-date with current information, best practices, and professional advice, articles are routinely reviewed by industry experts with years of hands-on experience. Bulk update symbol size units from mm to map units in rule-based symbology, How do you get out of a corner when plotting yourself into a corner, Relation between transaction data and transaction id, Follow Up: struct sockaddr storage initialization by network format-string. any idea of which applies to USA? How do I know what size grounding conductor is required? However, this spacing is a minimum. What Should Your Electrical Grounding Look Like. Aluminum wiring requires an antioxidant coating at the connection terminals to resist corrosion. You can consider using a junction box to extend the wire. Spring Design Apps 1-ft 18-Gauge Stranded Soft Drawn Copper Bare Wire (By-the-Foot) Model # 55024745. Find My Store. The grounding conductor will only carry a large amount of current for a very short time, allowing for a smaller gauge grounding conductor. Bearing Apps, Specs & Data Making statements based on opinion; back them up with references or personal experience. The American Wire Gauge (AWG) measurement system was designed with a purpose: for every three steps in the gauge scale, wire area (and weight per unit length) approximately doubles. For copper conductors, youll need a #2/0 AWG copper wire commonly used for electrical wiring because it is more heat resistant than aluminum. Can I use Schedule 40 PVC to protect a grounding electrode conductor where exposed to physical damage? Add To Cart. You can also use a hammer drill if you have one. This effectively grounds the RV to the generator. What's the difference between grounding bar and grounding rod? Videos Design Manufacture Can I use electrical tape to cover exposed wire? Youll need #4/0 AWG 200 amp wire size for aluminum or copper-clad aluminum wiring. BUT what applies currently varies by country and as grounding bars and rods all lead to ground in the country where the installation is (with a few very very unusual exceptions)(CERN would be interesting :-)) you need to check the regulations in the country of interest. What section of the NEC covers grounding? Just check the aluminum ground wire size table above and you will see that you need a 2 AWG aluminum ground wire for 00 AWG aluminum wire grounding. to this site, and use it for non-commercial use subject to our terms of use. What happens if ground wire is too small? Engineering Calculators The dryer the land, the more ground rods you should use. Learn more about Stack Overflow the company, and our products. Ground wires provide an alternative low-resistance path should any of the electrical equipment or enclosures become inadvertently energized. It is perfectly safe for household insulation to touch wires provided the wires or cables are electrically insulated. Feedback Advertising Basically, we are trying to answer what ground wire do you need for 200 amp service. If any person comes in contact with the ungrounded metal frame, he may suffer mild or severe electrical shock, depending on the potential there and various other conditions and factors at the place of installation. Expert insights on techniques and principles. The wires that bond your metal piping are preventative, and they only become important in the unlikely event that an electrical conductor energizes the pipe. Even though its more expensive, there is no harm in using a heavier gauge than you need. Below each chart, we also list some examples of ground wire sizing choices: What size ground wire do I need for a 3 AWG wire? Do ground wires need to be capped? Where there is a lot of electricity in the ground, a thicker #3 size wire may be required. Staff of Research and Education Association Threads & Torque Calcs 00 Cents / each. But to be used safely, grounding a generator is necessary. Another specific type of copper wire that is used for outdoor grounding would be the Green 6 THHN wire. The offered rate is exclusive of any bonus or promotional offers or redemption transactions. Likewise, on 233 volts on a 240-volt electrical circuit. Choose from our selection of copper grounding wire, including grounding wire, bonding and grounding clamps, and more. Does Voltage Drop Affect 200 Amp Wire Size? All rights reserved. Youll need to increase the AWG or kcmil wire size for long distances. Average 1-6 Person Home kWh Usage, Gas Vs Electric Water Heater Monthly Cost Comparison (State-By-State), Water Heating Costs For 1,2,3,4,5,6 Family Homes (State-By-State Analysis), Electric Water Heating Cost, kWh Usage Per Month (State-By-State RECS Analysis), What Is W2 Wire On Thermostat? About 200-Amp Service Wire Size The National Electrical Code mandates a maximum #2/0 AWG or #4/0 AWG copper wire coiled within a standard 1.5-inch PVC 40 or 80 conduits for underground service. The National Electrical Code (NEC) requires grounding electrode conductor size to be based on the sizes and types of conductors in the service. W2 Wire Thermostat Wiring (2nd Stage), Thermostat Wire Color Codes For 3-8 Wire Thermostats (Color-By-Color), How Many Therms Of Gas Per Month Is Normal? Be the first to rate this post. The standard ground wire color is either bare copper or green. Most home applications fall in this category as the transfer switches do not open or close the ground connection, and the system ground is permanently connected to the grid ground. ($0.05 $0.22/h), How Much Does 1000 Watts Cost Per Hour? MIN. This annealed copper is of medium-hard temper. Use the correct type of grounding rod. The wire and clamp are tightly secured to the ground rods top. Can I tell police to wait and call a lawyer when served with a search warrant? Hi @Russell, thanks for your post. The more current you need for something, the bigger the ground copper wire must be. To find the most optimum ground wire size, you have to consult the NEC Grounding Conduction Size Chart. Your copper grounding wire should also be in compliance with the relevant electrical code. It is used in a variety of uninsulated applications including electrical hook-ups, jumpers, and grounds. Ground-fault circuit interrupters (GFCIs) are sensitive devices that can detect very small current leaks and shut off power almost instantaneously. Get your weekly flyer email directly to you. GROUNDING ELECTRODE CONDUCTOR SIZING (Table 250.66)Size of Main PanelCopper ConductorsAluminum or Copper-Clad Aluminum125 Amps#8 AWG#6 AWG150 Amps#6 AWG#4 AWG200 Amps#4 AWG#2 AWG. They anticipate driving two ground rods to satisfy the 250.56 standards regardless of ground resistance. The following table of wire sizes does not show any sizes bigger than 4/0 gauge, because solid copper wire becomes impractical to handle at those sizes. Before the utility service can connect power to the house, youll need a Certificate of Occupancy (CO).

Garage Apartments For Rent Fort Worth, Do Lions Sleep With Their Eyes Open, Who Is The White Actress In The Jardiance Commercial, Miller And Carter Sevenoaks Car Park, Articles W

what gauge copper wire for grounding